Detector heads for JP-9710 and JX11 Series

 

 

 

 

JP-9710 (-2) & JX1 1 (-4) Laser Power Detectors

 
  

spectral

function*

(nm)

aperture

dia

(mm)

integrating

sphere

diameter

(mm)

 

typical

maximum

resolution

typical

maximum

value***

coating

JP-9710

JX1-1 HS

JP-9710

JX1-1 HS

JL-9901-2JLP-9901-4

Si

400 to

1100 nm

7

-

-

0.2 nW(633 nm)

2 nW(633 nm)

100 mW(633 nm)

10 mW(633 nm)

 

Si

400 to

1100 nm

12.5

50

BaSO4

0.5 nW(633 nm)

5 nW(633 nm)

5 W(900 nm)**

500 mW(900 nm)

JLP-0101-2

JLP-0101-4

InGaAs,

850 to 1700

nm

5

30

OP.DI.MA.

0.5 nW

(1500 nm)

5 nW

(1500 nm)

5 W

(1500 nm)**

500 mW

(1500 nm)

*Calibrated in 10 nm increments ***500mW CW

***values calculated based on current measurement capability and may be limited by operating temperature, power density and other factors

 

JP-9710 (-2) & JX1-1 (-4) Radiometric Irradiance Detectors

model

no.

spectral

function

( nm )

cosine

diffuser

dia

(mm)

typical

maximum

resolution

typical

maximum

value*

dimensions

(mm)

JP-9710 JX1-1 HS JP-9710 JX1-1 HS dia. height
JRW-3701-2 JRW-3701-4 400 to 500 BLUE 11 50 pW/cm² 500 pW/cm² 500 mW/cm² 50 mW/cm² 37 50
JRW-3702-2 JRW-3702-4 700 to 800 RED 11 50 pW/cm² 500 pW/cm² 500 mW/cm² 50 mW/cm² 37 50
JRW-3703-2 JRW-3703-4 400 to 800   11 50 pW/cm² 500 pW/cm² 500 mW/cm² 50 mW/cm² 37 50
JRW-3704-2 JRW-3704-4 800 to 1000 NIR 11 50 pW/cm² 500 pW/cm² 500 mW/cm² 50 mW/cm² 37 50
JRW-3705-2 JRW-3705-4 400 to 1000 VISNIR   25 pW/cm² 250 pW/cm² 250 mW/cm² 25 mW/cm² 37 50
JUV-3701-2 JUV-3701-4 315 to 400 UV-A 13 1.7 nW/cm² 17 nW/cm² 1.7 W/cm² 17 0 mW/cm² 37 32
JUV-3702-2 JUV-3702-4 280 to 315 UV-B 11 25 nW/cm² 250 nW/cm² 10 W/cm² 1 W/cm² 37 50
JUV-3703-2 JUV-3703-4 200/250 to 280 UV-C 11 5 nW/cm² 50 nW/cm² 2.5 W/cm² 250 mW/cm² 37 32
JUV-3710-2 JUV-3710-4 320 to 400 UV-A 11 2 nW/cm² 20 nW/cm² 2 W/cm² 200 mW/cm² 37 32
JUV-3711-2 JUV-3711-4 280 to 320 UV-B 11 33 nW/cm² 330 nW/cm² 10 W/cm² 1 W/cm² 37 50
JUV-3716-2 JUV-3716-4 305 to 400 UV-A 11 2 nW/cm² 20 nW/cm² 2 W/cm² 200 mW/cm² 37 32
JUV-3717-2 JUV-3717-4 315 to 400 UV-A 11 1.7 nW/cm² 17 nW/cm² 1.7 W/cm² 170 mW/cm² 37 32
JUV-3718-2 JUV-3718-4 250 to 280 UV-C 11 5 nW/cm² 50 nW/cm² 2.5 W/cm² 250 mW/cm² 37 32
*values calculated based on current measurement capability and may be limited by operating temperature, power density and other factors

JP-9710 (-2) & JX1 1 (-4) Photobiology Irradiance Detectors

model no.

spectral function (nm)

cosine

diffuser

diameter (mm)

typ. max. resolution

typ. max. value*

dimensions (mm)

JP-9710

JP-9710

JX1-1 LS

dia.

height

 

JUV-3704-2

JUV-3704-4

250 to 350

Erythema

11

3.3 nW/cm²eff

3.3 nW/cm²eff

1.7 W/cm²eff

17 mW/cm²eff

37

32

JUV-3706-2

JUV-3706-4

420 to 540

Bilirubin

11

50 pW/cm²eff

50 pW/cm²eff

500 mW/cm²eff

5 mW/cm²eff

37

32

JUV-3708-2

JUV-3708-4

210 to 400

UV Hazard

11

10 nW/cm²eff

10 nW/cm²eff

5 W/cm²eff

50 mW/cm²eff

37

50

JUV-3709-2

JUV-3709-4

380 to 540

BlueLightHazard

11

250pW/cm²eff

250 pW/cm²eff

1 W/cm²eff

10 mW/cm²eff

37

32

**values calculated based on current measurement capability and may be limited by operating temperature, power density and other factors

JP-9710 (-2) & JX1 1 (-4) UV-Curing Irradiance Detectors

model no. spectral
function (nm)
  aperture* (mm) typ. max. resolution typ. max. value** dimensions (mm)
        JP-9710   JP-9710 JX1-1 HS dia. height length

JRCH-008-2

JRCH-008-4

315-400 UVA 9 0.5 µW/cm² 0.1 mW/cm² 10 W/cm² 10 W/cm² 37 8 -

JRCH-009-2

JRCH-009-4

400-470 BLUE 9 0.3 µW/cm² 0.1 mW/cm² 10 W/cm² 10 W/cm² 37 8 -

JRCH-006-2

JRCH-006-4

250-400 UV broad band 9 0.5 µW/cm² 0.1 mW/cm² 10 W/cm² 10 W/cm² 37 8 -

JRCH-108-2

JRCH-108-4

  UVA 9 0.5 µW/cm² 0.1 mW/cm² 10 W/cm² 10 W/cm² 37 8 -
  400-470 BLUE 9 0.3 µW/cm² 0.1 mW/cm² 10 W/cm² 10 W/cm² 37 8 -

JRCH-106-2

JRCH-106-4

250-400 UV broad band 9 0.5 µW/cm² 0.1 mW/cm² 10 W/cm² 10 W/cm² 37 8 -

JRCH-208-2

JRCH-208-4

315-400 UVA 90° Rod 3x5 400 nW/cm² 4 µW/cm² 10 W/cm² 10 W/cm² 5 5 254

JRCH-209-2

JRCH-209-4

400-470 BLUE 90° Rod 3x5 2 µW/cm² 20 µW/cm² 10 W/cm² 10 W/cm² 5 5 254

JRCH-206-2

JRCH-206-4

250-400 UVBB 90° Rod 3x5 400 nW/cm² 4 µW/cm² 10 W/cm² 10 W/cm² 5 5 254

JRCH-308-2

JRCH-308-4

315-400 UVA 90° Rod 3x5 400 nW/cm² 4 µW/cm² 10 W/cm² 10 W/cm² 5 5 457

JRCH-309-2

JRCH-309-4

400-470 BLUE 90° Rod 3x5 2 µW/cm² 20 µW/cm² 10 W/cm² 10 W/cm² 5 5 457

JRCH-306-2

JRCH-306-4

250-400 UVBB 90° Rod 3x5 400 nW/cm² 4 µW/cm² 10 W/cm² 10 W/cm² 5 5 457
*the RCH-0xx and RCH-1xx can be used with adapters for light guides with 3, 5, and 8 mm dia.. Each independently calibrated
**values calculated based on current measurement capability and may be limited by operating temperature, power density and other factors

JP-9710 (-2) & JX1 1 (-4) Photometric Illuminance & Luminance Detectors

model no.

spectral function

 

cosine diffuser

 

units*

typ. max. resolution

typ. max. value**

dimensions (mm)

 

l

f1 (%)

diameter

f2 (%)

 

JP-9710

 

JP-9710

JX1-1 LS

dia.

ht/lgth

JVL-3701-2

V(l)

£ 3

7 mm

£ 1.5

lux / fc

0.2 mlx

 

1400 klx

 

37

20 H

JVL-3702-2

V(l)

£ 6

7 mm

£ 3

lux / fc

0.2 mlx

-

1400 klx

-

37

20 H

JVL-3704-4

V(l)

£ 6

7 mm

£ 3

lux / fc

-

10 mlx

-

200 klx

37

20 H

JLDM-9901-2

JLDM-9901-4

V(l)

£ 6

   

cd/m²

4 mcd/m²

4 mcd/m²

80 Mcd/m²

1000 kcd/m²

30

116 L

*detectors are calibrated in lux and foot-candles

**values calculated based on current measurement capability and may be limited by operating temperature, power density and other factors